Analog signal converters IN: 3 selactable ranges / OUT: 3 ranges
Series | CON |
---|---|
Code | XCONAA539P |
Type | CON-AA-539P (1) |
HS code | 85043129 |
INPUT TECHNICAL DATA | |
Signal type IN | analogue |
Input range IN | 0…10 V / 0…20 mA / 4…20 mA |
Input impedance IN | 330 kΩ (voltage input) / 100 Ω (current input) |
Parametrization IN | DIP switch |
OUTPUT TECHNICAL DATA | |
Signal type OUT | analogue |
Output range OUT | 0…10 V / 0…20 mA / 0…20 mA |
Maximum output signal OUT | 16 V (current output) / 5 mA (voltage output) |
Load impedance OUT | 2 KΩ (voltage output) /500 Ω (current output) |
Ripple | <20 mV |
Status indication | LED |
Parametrization OUT | DIP switch |
GENERAL TECHNICAL DATA | |
Power supply voltage | 24 Vac/dc (19.2…26.4 Vdc / 19.2…26.4 Vac) |
Accuracy | 0.1% FSR (23°C) |
Linearity error | 0.05% FSR |
Temperature coefficient | <150 ppm / K FSR |
Transmission frequency | 30 Hz |
Rise time | 6 ms |
Operating temperature range | -25…+60°C |
Insulation | 2.5 kVac / 60 s |
Insulation type | 3-way (IN / OUT / power) |
Standard approvals | EN 60947-5-1 |
Overvoltage category / pollution degree | II / 2 |
Protection degree | IP 20 |
Connection terminal IN / OUT | 2.5 mm² / 2.5 mm² (push-in) |
Housing material | UL94V-0 plastic material |
Dimensions (LxHxD) | 6.2x93x73 mm |
Approximate weight | 30g |
Mounting information | on a rail, side by side |
ACCESSORIES | |
Mounting rail (IEC60715/TH35-7.5) | PR/3/AC, PR/3/AC/ZB, PR/3/AS, PR/3/AS/ZB |
APPROVALS AND MARKINGS | ![]() ![]() |
For further information see PDF catalog
They convert electrical signals generated by sensors which take physical measure-ments such as temperature (thermocouples and PT100 resistance thermometers), frequency (proximity, contacts, photocells), current (TA, Hall sensors), resistance (potentiometers), voltage, pressure, level, etc. into standardised electrical signals, adapting them to PLC, DCS and industrial PC (control) outputs, or they convert a given analogue signal into a different one, adapting it to control inputs/outputs or allowing for long-distance signal transmission without interference by means of galvanic separation (fig. 1).
Adaptation between sensor output signal and control input signal
Long-distance signal transmission
Voltage signals can reach a max. distance of 10-20 m, beyond which they lose reliability and become highly sensitive to induced and ground-derived interference, therefore in order to transmit to distances beyond 20 m a voltage signal must be converted into a current signal and galvanically separated (fig. 2).
Current signals can surpass a transmission distance of 300 m and are less sensitive to induced interference. The long-distance transmission of a current signal requires galvanic separation.
Galvanic signal separation (signal isolation):
Copyright © Cabur srl Sede legale Località isola Grande, 45 – 17041 Altare (SV) – Italia – Tel. 019-589991 – Fax 019-58999233 – E-mail: info@cabur.it
Cap. Sociale: €2.000.000 Int. versato – Reg. Soc. Trib. Savona N° 4635 – C.C.I.A.A. N° 27269- Export N° SV 000532 – P.IVA e Cod. Fisc.: 00100760099
DISCLAIMER Cabur Srl may change and update any document available online without any obligation to inform users. Only cabur.it and cabur.eu domains are registered and maintained by Cabur srl. Cabur has no responsibility for contents published on sites under the same name, with different extensions from .it and .eu
for technical and commercial support
from monday to friday 8:30-12:30 13:00-17:00
+39 019 58999.219 customercare@cabur.it